Keeping the Heart Alive on Support

  • Insilico Medical Research
  • Research

Some injuries push the heart into territory where it cannot recover on its own, and clinical decision makers are tasked with deciding whether, and at what point, to take over the heart’s job entirely. The caveat is that while machines can do that well, for days at a time, every setting on them makes a physiological trade somewhere else.

When the heart has to be carried

VA-ECMO does two jobs at once: the pumping and the breathing. VA-ECMO stands for veno-arterial extracorporeal membrane oxygenation, wherein blood is drained from a large vein, pushed through a pump and an oxygenator outside of the body, and returned into an artery. Gas exchange and circulation both happen inside this circuit. For a while, neither the lungs nor the heart has to carry its usual share.

This is not only a battlefield technology. ECMO is an established therapy in civilian intensive care for respiratory and cardiopulmonary failure, including VA-ECMO for cardiogenic shock and refractory cardiac arrest. What draws researchers to it for complex injury, and for care that has to continue far from a hospital, is that it changes what “stabilized” can mean when evacuation is delayed.

That is the promise. What makes it hard is that support does not simply lift a burden off the heart. It relocates that burden, and the places it lands are coupled to each other, so one setting cannot be changed in isolation.

Support is not the same as rest

The intuition is that putting a patient on support lets the heart rest. That is partly true, and the part that is not true is where the physiological trades begin.

When the circuit returns blood into the femoral artery in the upper leg, that flow travels up the aorta, against the direction the left ventricle pushes. The pressure the ventricle has to overcome to open the aortic valve goes up. A strong ventricle manages this. A weak one may not open the valve at all.

When the valve stays shut, blood entering the left side of the heart has nowhere to go. The ventricle distends. Tension in the wall rises, which raises the oxygen demand of the muscle at the very moment the goal was to lower it. Pressure backs up into the lungs. Blood that is not moving is blood that can clot.

This is a well-described problem with established answers, which is why strategies to vent or unload the left ventricle exist alongside the support itself. The trade is still real. Support relieves one burden and creates another.

The improvement is the hazard

A recovering heart can create a problem that a failing one does not. The circuit puts well-oxygenated blood into the lower aorta. Once the ventricle starts pushing its own output again, through lungs that are still injured, that blood reaches the vessels leaving the top of the aorta first, which is to say the brain and the right arm. The body ends up perfused by two bloods at different oxygen levels, with the poorly oxygenated one going to the organ least able to tolerate it. Clinicians call this differential hypoxemia, and it is the reason oxygen saturation is monitored on the right hand specifically rather than wherever is convenient.

An improvement in one variable, the heart recovering, produced a hazard in a different organ entirely. The same pattern runs through every setting on the circuit.

Coming off is a question of how fast

Weaning from support returns load to a ventricle that has spent days not carrying it, and does so over a compressed window.

Earlier in this series we wrote about reperfusion injury, where the damage depends not just on whether blood flow comes back but on how fast it does. Weaning is the same class of problem. A step change in loading and supply arrives at tissue whose reserve is already reduced, and the rate of the change matters as much as the destination.

What this looked like at the symposium

The direction the field is heading was hard to miss at the Military Health System Research Symposium (MHSRS). Extracorporeal support is moving out of the intensive care unit and toward the point of injury. Circuits are being miniaturized, life support made portable, oxygenators built small enough to fit a payload instead of a room. Some of it is already in use in active conflict, in places where the technology arrived recently and the infrastructure around it has not caught up.

What the reports dwell on is rarely the pump. It is everything coupled to the pump. Blood thinners have to keep the circuit from clotting without turning a trauma patient into a bleeding one, and that balance is normally struck with laboratory monitoring that a forward setting does not have. Clinicians described cases in which the thinners were withheld for days, because the alternative was judged worse.

The problem gets harder as the technology moves forward, not easier. Every step toward the field adds a setting somebody has to choose, and takes away the instruments and the people who would ordinarily inform the choice.

Toward precision support

How fast the pump runs, how hard the heart is still contributing on its own, how much pressure it has to push against, how much fluid is on board, whether the ventricle is being vented, when to start the wean. None of these are independent knobs. Moving one moves the others. Clinicians reason about these couplings constantly and do it well, with real-time data and hard-won pattern recognition that no model replaces. What is missing is not judgment. It is a place to try a setting and watch the consequences propagate before committing a patient to it.

That is what the cardiac digital twin being developed under the MiCOR Insilico Shock Initiative (MiCOR ISI) is built toward, at the layer of the model where whole-body circulation meets tissue and the single cells underneath. A change in pump flow becomes a shift in wall stress, which raises what the muscle demands, which lands on the cells that have to supply it. Following that chain from end to end is the reason to build across scales instead of at one. MiCOR ISI is funded by the Uniformed Services University of the Health Sciences (USUHS) Military Cardiovascular Outcomes Research (MiCOR) program through a research agreement with The Metis Foundation.

No setting moves alone One setting, followed across four scales Pump flow rises the setting you turn Wall stress shifts in the ventricle Oxygen demand rises in the heart muscle Supply has to follow in the cells THE CIRCUIT THE CHAMBER THE MUSCLE THE CELLS Every other setting on the list starts a chain of its own the heart's own output pressure to push against fluid on board venting the ventricle when to start the wean
A single setting does not stay where it is set. Raising pump flow changes the pressure the ventricle works against, which changes what the heart muscle demands, which lands on the cells that have to supply it. Every other setting on the circuit starts a chain like it. A schematic of the coupling, not a model result.

We are not reporting from the far side of this. The circulation layer is where our current work is heaviest, and coupling it tightly enough to say something dependable about a specific ECMO setting is still ahead of us.

Next in this series, and last: how a mechanistic twin fits alongside the closed-loop algorithms that are already doing useful work.